Application
Furnace Control Board
Stages
Single Stage
Line Voltage
120 Vac (97-132 Vac)
Low Voltage
24V (18-30 Vac)
Frequency
60 Hz
Humidity Range
0% to 95% non-condensing
Ignitor
5A @ 120 VAC
Thermostat Anticipator Setting
(Stage 1 only) 100mA
Pre-purge
30 seconds
HSI Warmup Time
17/27 or 30/30 seconds
Trial for ignition
4, 6, or 8 seconds
PostPurge
15 seconds
Interpurge
60 seconds
Ignition Trials
Three, two tries if flame is not sensed
Number of LEDs
3
Brands Supported
Universal
- Universal Integrated Furnace Control Offers Universal Compatibility and Diagnostics
- It Replaces a Large Number of Furnace Control Models in Single-Stage Warm Air Furnaces
- Uses 120 Volt AC Hot Surface Igniter
- Cross Reference and Wire Harnesses Provided for Simple Replacement Over 195 Existing Furnace Controls
- Main Burner Ignition Using a 120 Volt Hot Surface Igniter
- Flame Rectification Circuit to Monitor Flame Presence
- Monitoring of System Pressure Switch, High Temperature Limit and Roll-Out Functions
- Appliance Operation/Safety Requirements Controlled Via Microprocessor
- Controls Circulating Fan Motor Based on Appliance Requirements, in Response to a Conventional Low Voltage Thermostat
- LED System Status, Performance and Diagnostic Indication
- Twinning Capability